Print

Power quality analyzer three phase

Power quality analyzer  three phase

Display per page
Sort by
  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS value (V123 and I123)
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)Energy (WH, KWH, KVARH, PFH)
  • Current measurement from 4A to 3000A, capable of analyzing IT standby power consumption to the maximum demand of a factory
  • Display of 35 Parameters in One Screen (3P4W
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in one Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples / Period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Optical Isolated RS-232C to USB Interface
  • Built-in timer and calendar for data logging
  • Option: 300XP Portable Thermal Printer
  • With AD3007 clamp up to 3000 A.
2,195.00 *

In stock
can be shipped within 3 days

  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS value (V123 and I123)
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)Energy (WH, KWH, KVARH, PFH)
  • Current measurement from 4A to 3000A, capable of analyzing IT standby power consumption to the maximum demand of a factory
  • Display of 35 Parameters in One Screen (3P4W
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in one Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples / Period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Optical Isolated RS-232C to USB Interface
  • Built-in timer and calendar for data logging
  • Option: 300XP Portable Thermal Printer

 

2,095.00 *

In stock
can be shipped within 3 days

  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS value (V123 and I123)
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)Energy (WH, KWH, KVARH, PFH)
  • Current measurement from 4A to 3000A, capable of analyzing IT standby power consumption to the maximum demand of a factory
  • Display of 35 Parameters in One Screen (3P4W
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in one Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples / Period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Optical Isolated RS-232C to USB Interface
  • Built-in timer and calendar for data logging
  • Option: 300XP Portable Thermal Printer

 

2,095.00 *

In stock
can be shipped within 3 days

  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS value (V123 and I123)
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)Energy (WH, KWH, KVARH, PFH)
  • Current measurement from 4A to 3000A, capable of analyzing IT standby power consumption to the maximum demand of a factory
  • Display of 35 Parameters in One Screen (3P4W
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in one Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples / Period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Optical Isolated RS-232C to USB Interface
  • Built-in timer and calendar for data logging
  • Option: 300XP Portable Thermal Printer
  • With AD3007 clamp up to 3000 A.
2,350.00 *

In stock
can be shipped within 3 days

Flexible clamps up to 3000 A
490.00 *

In stock
can be shipped within 3 days

*